📐 Local Pressure Coefficient (Cp)
Calculate local pressure coefficient from velocity/pressure differences in incompressible and compressible flows.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
Cfd
📊 Solver Telemetry
● ACTIVE
💡
Hardware & Sizing Partner: Need to size a control valve or check ASME flange bolt torque for this line?
📥 Pressures & Freestream Flow
📖 Mathematical Relations:
$$C_{p,0} = \frac{p - p_\infty}{\frac{1}{2}\rho V_\infty^2}, \quad M_\infty = \frac{V_\infty}{\sqrt{\gamma p_\infty / \rho}}$$
$$C_{p,\text{PG}} = \frac{C_{p,0}}{\sqrt{1 - M_\infty^2}}, \quad C_{p,\text{KT}} = \frac{C_{p,0}}{\sqrt{1-M_\infty^2} + \frac{M_\infty^2}{1+\sqrt{1-M_\infty^2}}\frac{C_{p,0}}{2}}$$
1.0000
Incompressible $C_{p,0}$
1.0462
Prandtl-Glauert ($C_{p,\text{PG}}$)
1.0226
Kármán-Tsien ($C_{p,\text{KT}}$)
M = 0.294
Freestream Mach ($M_\infty$)
💡
Aerodynamic Flow Diagnostic
At $M_\infty = \mathbf{0.294}$ and dynamic pressure $q_\infty = \mathbf{6.13\ \text{kPa}}$, this surface point has $\Delta p = \mathbf{6.13\ \text{kPa}$.}$
This location is near a flow stagnation point ($C_p \approx 1.0$).
📈 Compressibility Amplification: $C_p$ vs Mach Number $M_\infty$
🟢 Kármán-Tsien | 🔵 Prandtl-Glauert🔍 View Raw GNU Fortran Double-Precision Solver Output
MODE=1 MODE_NAME=Single Point P= 1.07450000E+05 P_INF= 1.01325000E+05 RHO= 1.22500000E+00 V_INF= 1.00000000E+02 GAMMA= 1.40000000E+00 Q_INF= 6.12500000E+03 CP= 1.000000 MACH= 0.293864 INTERPRETATION=Stagnation point
📘 Calculation Methodology: Pressure Coefficient & Compressibility Corrections
Mathematical Model & Theory
The pressure coefficient $C_p$ measures local static pressure relative to freestream dynamic pressure. Linear compressibility rules (Prandtl-Glauert, Kármán-Tsien) correct for subsonic density changes:
$$C_p = \frac{p - p_\infty}{\frac{1}{2}\rho_\infty V_\infty^2}, \quad C_{p,PG} = \frac{C_{p,0}}{\sqrt{1 - M_\infty^2}}$$
$$C_{p,KT} = \frac{C_{p,0}}{\sqrt{1 - M_\infty^2} + \frac{M_\infty^2}{1 + \sqrt{1 - M_\infty^2}}\frac{C_{p,0}}{2}}$$
Assumptions
- Inviscid, irrotational potential flow with small perturbations.
- Subcritical Mach number without local shock waves ($M_\infty < M_{cr}$).
Academic References
- Anderson, J. D.: Fundamentals of Aerodynamics, McGraw-Hill, Ch. 11.
- Liepmann, H. W., & Roshko, A.: Elements of Gasdynamics, Dover.
Worked Engineering Example
Problem Statement:
An airfoil has low-speed $C_{p,0} = -1.25$. Calculate the Prandtl-Glauert corrected $C_p$ at $M_\infty = 0.65$.
Step-by-step Solution:
1. $\beta = \sqrt{1 - 0.65^2} = \sqrt{0.5775} \approx 0.7599$.
2. $C_{p,PG} = -1.25 / 0.7599 \approx -1.645$.
Final Result:
Corrected pressure coefficient is $C_p = \mathbf{-1.645}$.
An airfoil has low-speed $C_{p,0} = -1.25$. Calculate the Prandtl-Glauert corrected $C_p$ at $M_\infty = 0.65$.
Step-by-step Solution:
1. $\beta = \sqrt{1 - 0.65^2} = \sqrt{0.5775} \approx 0.7599$.
2. $C_{p,PG} = -1.25 / 0.7599 \approx -1.645$.
Final Result:
Corrected pressure coefficient is $C_p = \mathbf{-1.645}$.