⚡ Restriction Orifice Sizer
Size thick-plate single or multi-hole restriction orifices (ISO 5167 / Crane TP410) for permanent pressure dissipation and cavitation check.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
28
⚡ Calculs faits
23
💾 Téléchargements
363
📦 Code Fortran
4.4 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
⚡ Thick-Plate Restriction Orifice Jet & Pressure Recovery
Real-time visual simulation of vena contracta jet contraction & permanent head loss📝 Configuration & Presets
💧 Pump Recirc (ΔP=20 bar)
🔥 Fuel Gas (ΔP=2.5 bar)
❄️ Chilled Water (ΔP=1.2 bar)
♨️ Multi-Hole Blowdown (55 bar)
Restriction Orifice Formulations:
• Permanent Loss Ratio: ΔPperm / ΔPo = 1 − β1.9
• Orifice Flow: Q = Cd · Ao · √[ (2 ΔPo) / ρ ] / √(1 − β⁴)
• Cavitation Index: σ = (P₂ − Pv) / ΔPperm
• Plate Thickness: tmin = do · √[ (3 ΔP) / (4 Sallow) ]
• Permanent Loss Ratio: ΔPperm / ΔPo = 1 − β1.9
• Orifice Flow: Q = Cd · Ao · √[ (2 ΔPo) / ρ ] / √(1 − β⁴)
• Cavitation Index: σ = (P₂ − Pv) / ΔPperm
• Plate Thickness: tmin = do · √[ (3 ΔP) / (4 Sallow) ]
📊 Restriction Sizing Results
📊 Output Summary
Calculated Orifice Bore Hole Size
do = 4.44 mm (7 holes)
Diameter Ratio: β = 0.1176 (d/D)
Plate Thk = 770 mm
Cavitation Index (σ)
0.45
🚨 SEVERE CHOKED CAVITATION / FLASHING
Downstream Pressure (P₂)
25.00 bar(a)
Permanent Loss = 55.00 bar
Orifice Bore Area
108.6 mm²
7 hole(s) × 15.5 mm²
Volumetric Flow Rate (Q)
26.32 m³/h
Discharge Cd = 0.62
📈 Orifice Bore Hole (do) vs Permanent ΔP
📉 Cavitation Index (σ) vs Pressure Drop
================================================================= THERMOFLUIDCALC — THICK-PLATE RESTRICTION ORIFICE REPORT ================================================================= Case Title : High-Pressure Boiler Continuous Blowdown Multi-Hole Plate Pipe Inside Diameter (D) : 100.00 mm Mass Flow Rate (W) : 25,000.0 kg/h Upstream Pressure (P1) : 80.00 bar(a) Downstream Pressure (P2) : 25.00 bar(a) Permanent Pressure Loss : 55.00 bar (5500.00 kPa) Number of Orifice Holes : 7 ----------------------------------------------------------------- ORIFICE BORE DIAMETER (do) : 4.445 mm each Diameter Ratio Beta (d/D) : 0.1176 Cavitation Index (Sigma) : 0.453 (🚨 SEVERE CHOKED CAVITATION / FLASHING) Recommended Plate Thickness: 770.0 mm =================================================================
📘 Calculation Methodology & Crane TP410 Standards
Permanent Pressure Loss Recovery
Unlike flowmeter orifices, restriction orifices are sized for permanent non-recoverable pressure dissipation based on Crane TP410 loss ratio:
ΔPperm / ΔPo = 1 − β1.9
Cavitation Index & Multi-Hole Plates
When $\sigma < 1.5$, severe cavitation erosion risks arise. Splitting the flow across multiple small holes or multi-stage plates elevates cavitation resistance.
Key Engineering Assumptions
- Square-edged thick restriction orifice plate ($t \ge 0.05 D$).
- Discharge coefficient $C_d = 0.62$ in high Reynolds turbulent flow.
- Stainless steel 316 / Monel plate bending stress limit per ASME Section VIII.