🛡️ PSV Sizing (API 520 / 526)

Size pressure safety relief valve orifice areas according to API RP 520 / API 526 for gas, steam, and liquid relief with backpressure derating.

⚡ Fortran 90 Engine Double Precision (IEEE 754) ✓ ISO / ASME Validated
📊 Solver Telemetry ● ACTIVE
👁️ Consultations 40
⚡ Calculs faits 32
💾 Téléchargements 220 📦 Code Fortran 4.4 KB
📅 Mise en service Jun 2026
⏱️ Latence < 1 ms
⚡ Outils & Rapports :
💾 Télécharger Fortran 90

🛡️ API 526 Spring-Loaded Relief Valve Dynamic Lift & Discharge Plume

Real-time visual simulation of spring compression & sonic nozzle expansion

📝 Configuration & Presets

🔥 Methane Separator (25 bar) ♨️ Steam Header (40 bar) 💧 Liquid Thermal Relief (16 bar) 🚒 Fire Emergency Case (16%)
⚙️ Service & Pressure Settings
Superimposed + Built-up backpressure
Standard: 10% (Operating), 16% / 21% (Fire case)
🌡️ Relief Conditions & Required Flow
API 520 Sizing Formulations:
• Gas Choked: A = [W / (C · Kd · P₁ · Kb)] · √[(T · Z) / M]
• Steam: A = W / (51.5 · Kd · P₁ · Kb)
• Liquid: A = W / [11.78 · Kd · Kw · √(ρ · ΔP)]
• Relieving Pressure: P₁ = Pset · (1 + Overpressure) + Patm

📊 Sizing Results & Orifice Selection

📊 Output Summary
💾 Fortran Source

Recommended API 526 Standard Orifice
Orifice Letter "K"
Standard Area = 1,186.0 mm² (1.838 in²)
+35.9% Overcapacity
Required Orifice Area (Areq) 872.6 mm² 1.3525 sq.in
Rated Orifice Capacity (Wrated) 20,388 kg/h Required = 15,000 kg/h
Relieving Pressure (P₁) 28.51 bar(a) Backpressure = 2.51 bar(a)
Discharge Coefficient (Kd) 0.975 Backpressure Factor Kb = 1.000

📈 Required Orifice Area vs Set Pressure

📊 Standard API 526 Orifice Capacities

=================================================================
 THERMOFLUIDCALC — API 520 / 526 RELIEF VALVE SIZING REPORT
=================================================================
Case Title                 : Natural Gas / Methane Production Separator PSV
Service Mode               : Gas/Vapor
Set Pressure (P_set)       : 25.00 bar(g)
Overpressure Allowance     : 10.0 %
Relieving Pressure (P1)    : 28.513 bar(a) (2851.33 kPa a)
Backpressure (Pb)          : 2.513 bar(a) (251.33 kPa a)
Required Mass Flow (W)     : 15,000.0 kg/h
-----------------------------------------------------------------
Calculated Required Area   : 872.58 mm2 (1.3525 sq.in)
Selected API 526 Orifice   : Letter [K]
API 526 Standard Area      : 1186.00 mm2 (1.8383 sq.in)
Rated Orifice Flow Rate    : 20,387.9 kg/h
Overcapacity Margin        : +35.92 %
=================================================================

📘 Calculation Methodology & Engineering Standards

API 520 Part I Formulations

For compressible vapors and gases under critical (choked) flow conditions where $P_b / P_1 \le [2/(k+1)]^{k/(k-1)}$:

A = [W / (C · Kd · P₁ · Kb)] · √[(T · Z) / M]

Discharge coefficient $K_d = 0.975$ with certified derating factor applied per ASME Sec VIII.

API 526 Standard Orifice Letters

Standardized letter designations from D ($0.110\,\text{in}^2$) through T ($26.0\,\text{in}^2$) specify minimum effective nozzle flow areas for flanged safety relief valves.

Key Engineering Assumptions

  • Certified effective coefficient of discharge $K_d = 0.975$ (gas/steam) or $0.65$ (liquid).
  • Ideal gas behavior corrected with compressibility factor $Z$.
  • Backpressure derating factor $K_b$ evaluated for conventional or balanced bellows valves.