📐 Pipe Support Span (ASME B31)
Determine maximum allowable pipe span and support spacing based on sag deflection limits (2.5 mm) and ASME B31 allowable bending stress.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
31
⚡ Calculs faits
25
💾 Téléchargements
171
📦 Code Fortran
4.4 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
📐 Multi-Span Continuous Pipe Deflection & Support Stanchions
Real-time visual simulation of elastic beam sag under gravity & insulation weight📝 Configuration & Presets
ASME B31 Span Formulations:
• Total Weight: w = wpipe + wfluid + wins [N/m]
• Deflection Limit: Lδ = [ (384 E I δallow) / (5 w) ]¼
• Stress Limit: Lσ = √[ (8 Z Sallow) / w ], with Sallow ≤ 0.23 Sh
• Maximum Allowable Span: Lmax = min(Lδ, Lσ)
• Total Weight: w = wpipe + wfluid + wins [N/m]
• Deflection Limit: Lδ = [ (384 E I δallow) / (5 w) ]¼
• Stress Limit: Lσ = √[ (8 Z Sallow) / w ], with Sallow ≤ 0.23 Sh
• Maximum Allowable Span: Lmax = min(Lδ, Lσ)
📊 Pipe Span Results
📊 Output Summary
Recommended Maximum Support Spacing
Lmax = 10.28 meters (33.7 ft)
Governing Criterion: Deflection Limit (Sag ≤ 3.0 mm)
w = 966.7 N/m
Deflection-Limited Span (Lδ)
10.28 m
Sag Limit = 3.0 mm
Stress-Limited Span (Lσ)
17.39 m
Sallow = 31.7 MPa
Pipe Steel Linear Weight
914.7 N/m
93.2 kg/m
Fluid + Insulation Weight
52.0 N/m
Fluid = 52.0 N/m, Ins = 0.0 N/m
📈 Maximum Allowable Span vs Standard Pipe Size (NPS)
📉 Midspan Sag Deflection vs Support Spacing
================================================================= THERMOFLUIDCALC — ASME B31.1 / B31.3 PIPE SPAN REPORT ================================================================= Case Title : 16" Natural Gas Transmission Header Outside Diameter (Do) : 406.40 mm Wall Thickness (t) : 9.53 mm Elastic Modulus (E) : 200.0 GPa Material Allowable Sh : 138.0 MPa Total Distributed Weight : 966.71 N/m (98.54 kg/m) ----------------------------------------------------------------- Deflection-Limited Span : 10.28 meters (33.72 ft) Stress-Limited Span : 17.39 meters (57.07 ft) RECOMMENDED MAXIMUM SPAN : 10.28 meters (33.72 ft) Governing Criterion : Deflection Limit (Sag ≤ 3.0 mm) =================================================================
📘 Calculation Methodology & ASME Standards
Deflection Limit Criterion
To prevent liquid pocketing, condensate pooling, and excessive slope distortions in drainage lines, sag is restricted to $2.54\,\text{mm}$ ($0.1\,\text{in}$):
Lδ = [ (384 E I δallow) / (5 w) ]¼
ASME B31 Sustained Bending Stress
Weight bending stress is allocated a budget $S_b \le 0.23 S_h$ to preserve allowable stress margin for internal pressure and thermal expansion.
Key Engineering Assumptions
- Uniform continuous multi-span beam behavior with simple supports.
- Combined weight includes pipe steel, fluid contents, and insulation jacket.
- No concentrated heavy valves at midpoint (if present, span should be reduced by 30–40%).