🌪️ Agitator Power & Mixing Time
Compute industrial agitator shaft power draw, specific power (W/m³), liquid pumping rate, and 95% homogenization blending time.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
17
⚡ Calculs faits
15
💾 Téléchargements
355
📦 Code Fortran
4.4 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
🌪️ Baffled Mixing Tank Vortex & Turbulent Streamlines
Real-time visual simulation of impeller rotation, liquid pumping flow & tracer dispersion📝 Configuration & Presets
🧪 Rushton Turbine (120 RPM)
🌊 Hydrofoil Flocculator (45 RPM)
🎨 Pitched Blade (850 cP)
🍯 Anchor Impeller (25k cP)
Mixing Formulations:
• Impeller Reynolds: Re = (ρ · N · D²) / μ
• Shaft Power: P = Np · ρ · N³ · D⁵ [Watts]
• Pumping Rate: Qp = Nq · N · D³ [m³/s]
• 95% Mixing Time: θ₉₅ = [ 5.4 / (N · Np⅓) ] · (T/D)²
• Impeller Reynolds: Re = (ρ · N · D²) / μ
• Shaft Power: P = Np · ρ · N³ · D⁵ [Watts]
• Pumping Rate: Qp = Nq · N · D³ [m³/s]
• 95% Mixing Time: θ₉₅ = [ 5.4 / (N · Np⅓) ] · (T/D)²
📊 Agitation & Power Results
📊 Output Summary
Shaft Power & Motor Sizing
Pshaft = 0.37 kW (0.49 HP)
Recommended Motor (1.25x SF): 0.46 kW
11 W/m³
95% Homogenization Time (θ₉₅)
86.9 seconds
1.45 minutes
Impeller Reynolds Number (Re)
1.08e+6
Turbulent Flow
Liquid Pumping Flow Rate (Qp)
2,566 m³/h
Turnover Time = 47.2 s
Power Number (Np)
0.35
Pumping Number Nq = 0.55
📈 Shaft Power Draw vs Agitator Speed (RPM)
📉 95% Blending Time vs Agitator Speed
================================================================= THERMOFLUIDCALC — INDUSTRIAL AGITATOR & MIXING REPORT ================================================================= Case Title : Wastewater Treatment Flocculator with Axial Hydrofoil Impeller Configuration : Hydrofoil / Marine Propeller (Axial) Tank Diameter / Height : 3.50 m / 3.50 m Impeller Diameter (D) : 1.20 m (D/T = 0.34) Agitator Speed (N) : 45.0 RPM (0.75 rev/s) Impeller Reynolds (Re) : 1.08e+6 ----------------------------------------------------------------- SHAFT MECHANICAL POWER : 0.37 kW (0.49 HP) Specific Power Draw (P/V) : 10.9 W/m3 (0.01 kW/m3) Primary Pumping Flow (Qp) : 2,566.1 m3/h 95% BLENDING MIXING TIME : 86.91 seconds (1.45 min) Recommended Motor Rating : 0.46 kW =================================================================
📘 Calculation Methodology & Mixing Theory
Power Draw Scaling Law
Shaft power scales cubically with rotation speed $N^3$ and with the 5th power of diameter $D^5$ in the turbulent regime:
P = Np · ρ · N³ · D⁵
Grenville 95% Mixing Time
The 95% homogenization time $\theta_{95}$ predicts complete batch blending based on turbulent macro-mixing turnover loops.
Key Engineering Assumptions
- Single impeller mounted on central vertical shaft ($C = T/3$ off bottom).
- Standard full liquid volume $H \approx T$.
- Motor safety service factor $SF = 1.25$ applied for viscous startup surges.