🔄 Supercritical CO2 Recompression Brayton

Size closed-loop supercritical CO2 (sCO2) recompression Brayton power loops: thermal efficiency (>45%), net electrical power (MW), split recompression ratio, and dual recuperator duties.

⚡ Fortran 90 Engine Double Precision (IEEE 754) ✓ ISO / ASME Validated
📊 Solver Telemetry ● ACTIVE
👁️ Consultations 38
⚡ Calculs faits 33
💾 Téléchargements 360 📦 Code Fortran 11.4 KB
📅 Mise en service Jun 2026
⏱️ Latence < 1 ms
⚡ Outils & Rapports :
💾 Télécharger Fortran 90

⚛️ Closed-Loop sCO2 Recompression Power Cycle & Dual Recuperators

Real-time visual simulation: Dense-phase main compressor + bypass recompressor with LTR/HTR heat recovery

📝 Configuration & Presets

⚛️ Gen-IV Nuclear (650°C) ☀️ Solar Tower CSP (700°C) 🔥 Allam Oxy-Fuel (1100°C) 🏭 SMR Compact sCO2 (550°C)
⚡ Operating Pressures & Temperatures
1 MPa = 10 bar
Near critical point (7.38 MPa)
⚙️ Mass Flow & Split Recompression
Fraction bypassing precooler to RC
sCO2 Recompression Brayton Formulation:
• Net Cycle Work: wnet = wt − (1−γ)·wMC − γ·wRC [kJ/kg]
• Thermal Efficiency: ηth = wnet / qheater [%]
• Dense-phase compression near critical point (ρ ≈ 600 kg/m³) drastically cuts pump work.
• Dual recuperators (LTR & HTR) eliminate pinch-point heat exchange mismatch.

📊 sCO2 Cycle Results

📊 Output Summary
💾 Fortran Source

Net Electrical Power Output (Ẇnet)
13.72 MW
Thermal Efficiency: 37.69 % | Reactor Duty: 36.4 MW
Phigh = 22 MPa (220 bar)
Gross Turbine Power (Ẇt) 19.46 MW ηt = 90 %
Main Compressor Power (MC) 2.24 MW Flow = 65 %
Recompressor Power (RC) 3.50 MW γ = 35 %
Precooler Heat Rejection 22.68 MW Low-temp heat sink

📈 Thermal Efficiency η (%) vs Recompression Fraction γ

📉 Net Power Output W_net (MW) vs Turbine Inlet Temp TIT (°C)

=================================================================
 THERMOFLUIDCALC — SUPERCRITICAL CO2 RECOMPRESSION BRAYTON REPORT
=================================================================
Case Title                 : Concentrated Solar Power (CSP) Central Solar Tower sCO2
Pressure Range             : P_high = 22.00 MPa (220.0 bar), P_low = 7.50 MPa (75.0 bar)
Temperatures & Mass Flow   : TIT = 700.0 C, MC Inlet = 35.0 C, Total m_dot = 80.0 kg/s
Split Recompression Ratio  : gamma = 0.350 (RC flow = 28.0 kg/s, MC flow = 52.0 kg/s)
-----------------------------------------------------------------
NET ELECTRICAL POWER (Wnet): 13.719 MW (13719.2 kW)
CYCLE THERMAL EFFICIENCY   : 37.690 %
Gross Turbine Power Output : 19.457 MW
Main Compressor Power (MC) : 2.237 MW
Recompressor Power (RC)    : 3.501 MW
Main Heater / Reactor Duty : 36.400 MW
Precooler Heat Rejection   : 22.681 MW
=================================================================

📘 Calculation Methodology & sCO2 Brayton Standards

Near-Critical Compression Advantage

Compressing supercritical $CO_2$ just above its critical point ($31.1^\circ\text{C}, 7.38\,\text{MPa}$) exploits high density ($\sim 600\,\text{kg/m}^3$), reducing compressor power consumption by over $60\%$ compared to ideal gases.

Split-Flow Recompression Architecture

The recompression compressor (RC) takes a fraction $\gamma$ of hot low-pressure fluid directly from the LTR outlet without cooling, perfectly matching the specific heat capacitance rates ($mc_p$) across the recuperator.

Key Engineering Assumptions

  • Closed-loop closed Brayton cycle with pure $CO_2$.
  • Dual printed-circuit heat exchangers (PCHE) for LTR and HTR.
  • Applicable to Gen-IV nuclear reactors, solar tower CSP, and waste heat recovery.