🚀 Solar Thermal Ejector Refrigeration
Model solar-driven supersonic ejector refrigeration: entrainment ratio (omega), thermal COP, required solar collector field area (m²), and compressor-free cooling capacity.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
43
⚡ Calculs faits
36
💾 Téléchargements
391
📦 Code Fortran
11.4 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
🚀 Supersonic Ejector Nozzle & Solar Thermal Refrigeration Loop
Real-time visual simulation: High-pressure primary motive steam entraining secondary evaporator vapor through supersonic mixing📝 Configuration & Presets
☀️ Solar Building AC (R245fa)
💨 Industrial Steam Jet Chiller (Water)
🔥 CSP Parabolic Trough (R600a)
🏠 Solar Flat Plate Cooler (R134a)
Solar Ejector Refrigeration Formulation:
• Entrainment Ratio: ω = ṁsec / ṁpri ∝ √[(Tg−Tc)/(Tc−Te)]
• Thermal COP: COPth = Q̇cool / Q̇solar_gen
• Required Solar Area: Asolar = Q̇gen / (G · ηcoll) [m²]
• Completely compressor-free thermal refrigeration.
• Entrainment Ratio: ω = ṁsec / ṁpri ∝ √[(Tg−Tc)/(Tc−Te)]
• Thermal COP: COPth = Q̇cool / Q̇solar_gen
• Required Solar Area: Asolar = Q̇gen / (G · ηcoll) [m²]
• Completely compressor-free thermal refrigeration.
📊 Solar Ejector Results
📊 Output Summary
Required Solar Collector Field Area
33.5 m²
Thermal COP: 0.850 | Solar Heat Duty: 17.6 kW
ω = 0.521
Entrainment Ratio (ω)
0.521
ṁsec / ṁpri
Thermal COP (Q̇c / Q̇gen)
0.850
Zero mechanical work
Primary Motive Flow
0.148 kg/s
From solar boiler
Secondary Suction Flow
0.077 kg/s
From evaporator
📈 Entrainment Ratio ω vs Solar Generator Temp Tg (°C)
📉 Solar Collector Area A_solar (m²) vs Cooling Power Q_cool (kW)
================================================================= THERMOFLUIDCALC — SOLAR THERMAL EJECTOR REFRIGERATION REPORT ================================================================= Case Title : Solar Evacuated Tube Building Air Conditioning (R245fa) Refrigerant Fluid : R245fa (Low-Pressure HFC) Operating State Temps : Generator Tg = 95.0 C, Evaporator Te = 7.0 C, Condenser Tc = 34.0 C Solar Radiation & Field : Irradiance G = 850.0 W/m2, Collector Efficiency = 0.62 ----------------------------------------------------------------- SUPERSONIC ENTRAINMENT (w) : 0.5210 (Secondary / Primary Mass Flow Ratio) THERMAL COP (COP_th) : 0.8500 REQUIRED SOLAR FIELD AREA : 33.49 m2 Solar Generator Heat Duty : 17.65 kW Motive / Suction Flows : m_pri = 0.1476 kg/s, m_sec = 0.0769 kg/s =================================================================
📘 Calculation Methodology & Solar Ejector Standards
Supersonic Jet Entrainment
High-pressure motive vapor expands through a convergent-divergent nozzle to supersonic speeds ($M > 2$), creating a low-pressure zone that sucks vapor from the evaporator.
100% Thermal Drive (No Compressor)
Solar thermal energy directly powers the cycle. Only a tiny liquid feed pump is required, consuming less than $1\%$ of the electrical energy of vapor compression chillers.
Key Engineering Assumptions
- 1D gas dynamic model of supersonic constant-pressure mixing.
- Saturated vapor conditions at generator and evaporator exits.
- Applicable to solar air conditioning, industrial steam ejectors, and food cold storage.