💧 Falling Film Evaporator & Desalination Sizer
Size falling film evaporators and MED desalination plants: Chun & Seban falling film correlation, minimum wetting rate, vapor generation rate, and steam economy.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
35
⚡ Calculs faits
27
💾 Téléchargements
367
📦 Code Fortran
4.1 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
💧 Falling Wavy Liquid Film & Steam Condensation Jacket
Real-time visual simulation: Gravity falling liquid film with vapor bubbles and outer condensing steam📝 Configuration & Presets
🌊 Seawater MED Desalination
🥛 Skim Milk Concentration
🪵 Black Liquor Evaporator
🎋 Sugar Juice Evaporation
Chun & Seban Falling Film Model:
• Peripheral Wetting: Γ = ṁfeed / (Nt · π · Di) [kg/(m·s)]
• Film Reynolds: Ref = 4 Γ / μL
• Minimum Wetting Criteria: Γmin ≥ 0.04 kg/(m·s) (Prevents tube dryout & scaling)
• Evaporation Duty: Q̇ = U · A · (Tsteam − Tevap) [kW].
• Peripheral Wetting: Γ = ṁfeed / (Nt · π · Di) [kg/(m·s)]
• Film Reynolds: Ref = 4 Γ / μL
• Minimum Wetting Criteria: Γmin ≥ 0.04 kg/(m·s) (Prevents tube dryout & scaling)
• Evaporation Duty: Q̇ = U · A · (Tsteam − Tevap) [kW].
📊 Evaporation Performance Results
📊 Output Summary
Evaporated Vapor Production Rate
2903 kg/h (0.81 kg/s)
Thermal Duty: 1891.0 kW (1.89 MW) | Area: 83.6 m²
SAFE (FULL WETTING FILM)
Wetting Rate (Γ)
0.100 kg/(m·s)
Dryout limit = 0.04 kg/(m·s)
Falling Film Coeff (hfilm)
2072 W/(m²·K)
Overall U = 1509 W/(m²·K)
Film Reynolds Number (Ref)
222
Laminar wavy film
Effective Temp Difference (ΔT)
15.0 °C
Steam 95 °C → Evap 80 °C
📈 Evaporated Vapor Rate ṁevap (kg/h) vs Tube Count Nt
📊 Film Coeff hfilm [W/(m²·K)] vs Wetting Rate Γ [kg/(m·s)]
================================================================= THERMOFLUIDCALC — FALLING FILM EVAPORATOR SIZING REPORT ================================================================= Case Title : Sugar Cane Juice Falling Film Evaporator Feed Liquid Medium : Sugar Cane Juice (Syrup Concentration) Operating Temperatures : Tfeed = 75.0 C, Tsteam = 95.0 C, Tevap = 80.0 C Tube Bundle Geometry : Nt = 140 tubes, Di = 38.0 mm, Length L = 5.00 m ----------------------------------------------------------------- PERIPHERAL WETTING RATE (Γ): 0.0997 kg/(m.s) (SAFE (FULL WETTING FILM)) FILM REYNOLDS NUMBER (Ref) : 222 Falling Film Coeff (h_film): 2072.1 W/(m2.K) Overall Heat Transfer (U) : 1508.6 W/(m2.K) Total Evaporator Area : 83.57 m2 THERMAL HEAT DUTY (Q) : 1891.00 kW (1.891 MW) EVAPORATED VAPOR PRODUCTION: 2903.0 kg/h (0.81 kg/s) =================================================================
📘 Calculation Methodology & Falling Film Standards
Thin Wavy Liquid Film Evaporation
Falling film evaporators operate with liquid descending as a thin film along the inner wall of vertical tubes under gravity, enabling very high heat transfer coefficients and low residence times.
Minimum Wetting Rate ($\Gamma_{min}$)
Maintaining adequate liquid flow per perimeter prevents dry spots, which cause severe fouling, scaling, and tube burnout.
Key Engineering Assumptions
- Chun & Seban turbulent and laminar falling film correlation.
- Saturated steam condensation on the outer shell side.
- Widely used in multi-effect distillation (MED) seawater desalination, milk powder plants, and black liquor recovery.