🔥 Flow Boiling Critical Heat Flux & DNB
Size flow boiling Critical Heat Flux (q_CHF), Minimum Departure from Nucleate Boiling Ratio (MDNBR safety margin), and dryout vapor quality using Bowring and Katto-Ohno models.
⚡ Fortran 90 Engine
Double Precision (IEEE 754)
✓ ISO / ASME Validated
📊 Solver Telemetry
● ACTIVE
👁️ Consultations
27
⚡ Calculs faits
21
💾 Téléchargements
336
📦 Code Fortran
10.8 KB
📅 Mise en service
Jun 2026
⏱️ Latence
< 1 ms
🔥 Vertical Flow Boiling Regimes & DNB / Dryout Front
Real-time visual simulation: Single-Phase → Bubbly Flow → Slug/Annular → Critical Heat Flux Dryout Hotspot📝 Configuration & Presets
Bowring / Katto Flow Boiling CHF Formulation:
• Critical Heat Flux: q″CHF = [ A′ + ¼ D G Δhsub ] / (C′ + L) [kW/m²]
• Minimum DNB Ratio: MDNBR = q″CHF / q″actual (Safety Margin > 1.3)
• Critical Power: Qcrit = q″CHF · (π D L) [kW]
• Critical Exit Quality: xcrit = (Qcrit − G Aflow Δhsub) / (G Aflow hfg)
• Critical Heat Flux: q″CHF = [ A′ + ¼ D G Δhsub ] / (C′ + L) [kW/m²]
• Minimum DNB Ratio: MDNBR = q″CHF / q″actual (Safety Margin > 1.3)
• Critical Power: Qcrit = q″CHF · (π D L) [kW]
• Critical Exit Quality: xcrit = (Qcrit − G Aflow Δhsub) / (G Aflow hfg)
📊 CHF & DNB Margin Results
📊 Output Summary
Critical Heat Flux (q″CHF)
q″CHF = 100 kW/m²
Applied Flux: 450 kW/m² | MDNBR Margin: 0.22
BURNOUT RISK (MDNBR < 1.3)
Safety Ratio (MDNBR)
0.22
Requires heat reduction
Critical Channel Power (Qcrit)
117.8 kW
Dryout thermal limit
Saturation Temp (Tsat)
357.3 °C
hfg = 600 kJ/kg
Critical Exit Quality (xcrit)
0.047
Subcooled/DNB departure
📈 Critical Heat Flux q″_CHF vs Mass Flux G [kg/(m²·s)]
📉 MDNBR Safety Ratio vs Applied Heat Flux q″ [kW/m²]
================================================================= THERMOFLUIDCALC — FLOW BOILING CRITICAL HEAT FLUX (CHF/DNB) REPORT ================================================================= Case Title : Subcritical / Supercritical Utility Boiler Waterwall Tube Channel Dimensions : Inside Diameter D = 25.00 mm, Heated Length L = 15.00 m Operating Parameters : Mass Flux G = 1800.0 kg/(m2.s), Pressure P = 180.0 bar (Tsat = 357.3 C) Inlet Subcooling : 25.0 C (Delta h_sub = 105.0 kJ/kg) Applied Actual Heat Flux : 450.0 kW/m2 ----------------------------------------------------------------- CRITICAL HEAT FLUX (q_CHF) : 100.0 kW/m2 MINIMUM DNB RATIO (MDNBR) : 0.222 [UNSAFE / DNB RISK] CRITICAL CHANNEL POWER : 117.81 kW Critical Exit Vapor Quality: 0.0472 =================================================================
📘 Calculation Methodology & Critical Heat Flux Standards
Bowring & Katto-Ohno Correlation
Calculates the peak convective heat flux before bubble overcrowding prevents liquid wall replenishment:
q″CHF = [ A′ + ¼ D G Δhsub ] / (C′ + L)
DNB vs Annular Liquid Dryout
At high subcooling and high mass flux, CHF occurs by Departure from Nucleate Boiling (DNB). At higher qualities, it occurs by dryout of the annular liquid film.
Key Engineering Assumptions
- Uniform axial heat flux profile in vertical round tubes.
- Saturated and subcooled water-steam flow regimes.
- Design criteria: $MDNBR \ge 1.30$ margin against thermal burnout.