  ThermoFluidCalc — Offline Fortran Execution Guide
=========================================================================

Calculator : Flat Plate Convection
Category   : Convection

Files Included:
  - flat_plate_convection.f90 (Fortran Source Code)
  - input.txt (Pre-configured Sample Input)

-------------------------------------------------------------------------
1. How to Compile
-------------------------------------------------------------------------
Make sure you have a Fortran compiler installed (like gfortran).
Run the following compilation command in your terminal:

  gfortran -O3 flat_plate_convection.f90 -o flat_plate_conv

-------------------------------------------------------------------------
2. How to Execute
-------------------------------------------------------------------------
Run the compiled binary and redirect the input.txt file into stdin:

  flat_plate_conv < input.txt

-------------------------------------------------------------------------
3. Input File Details
-------------------------------------------------------------------------
The input file 'input.txt' contains sequential parameters separated by
newlines. Here is the structure of the included 'input.txt':

  Line 1 (Plate Length L [m]
): 1.0
  Line 2 (Plate Width W [m]
): 0.5
  Line 3 (Surface Temp Ts [Â°C]
): 80.0
  Line 4 (Free Stream Temp Tinf [Â°C]
): 20.0
  Line 5 (Free Stream Velocity U [m/s]
): 5.0
  Line 6 (Fluid Density [kg/m3]
): 1.092
  Line 7 (Dynamic Viscosity [Pa-s]
): 1.963e-5
  Line 8 (Thermal Conductivity k [W/m-K]
): 0.02735
  Line 9 (Prandtl Number Pr
): 0.7228
  Line 10 (Specific Heat Cp [J/kg-K]): 1007.0

=========================================================================
ThermoFluidCalc — https://thermofluidcalc.com