๐Ÿ”ฌ Venturi & Nozzle Flow Meter Calculator

Calculate volume and mass flow rate through venturi meters and flow nozzles using ISO 5167-style discharge coefficient, ฮฒ ratio, and differential pressure.

๐Ÿ”ง Venturi Meter Schematic

๐Ÿ“ Configuration

๐Ÿ“ Geometry
๐Ÿ’ง Fluid Properties
๐Ÿ“‰ Operating Conditions
1.0 for incompressible; <1 for compressible gas.
Leave 0 for ISO-style automatic Cd.
Key Equations:

Q = Cd ฮณ E A2 โˆš(2ฮ”P/ฯ)
E = 1/โˆš(1โˆ’ฮฒโด), ฮฒ = d/D
Cd from simplified Reader-Harris/Gallagher correlation.

๐Ÿ“Š Results

Configure inputs and click Calculate to view results.

๐Ÿ“˜ Calculation Methodology

Mathematical Model

The flow rate is derived from Bernoulli's equation applied between the pipe upstream section and the throat. The discharge coefficient corrects for real-fluid effects.

Worked Example

For a 100 mm pipe with 50 mm throat, water at 25ยฐC and ฮ”P = 25 kPa, the engine iterates Cd, computes Q and reports the operating Reynolds number.

Assumptions

  • Steady, incompressible flow (or with expansion factor for gas).
  • ISO 5167-style venturi discharge coefficient correlation.
  • Fully developed upstream velocity profile.
  • No cavitation check included.